The Lauritz Knudsen XD2000-07P2-4B1121 is a Frame 1, 3 kW variable frequency drive for 3-phase 415V motor control, purpose-built for fan, pump, and compressor duty with built-in PID and Modbus connectivity. CE & RoHS certified.

  • Rated output: 2.2 kW (HD) / 3 kW (ND) — 5.6 A (HD) / 7.2 A (ND)
  • Supply: 380–460VAC (-15/+10%), 3-phase, 50/60Hz
  • Control: V/F 5-point, Slip Compensation, Quadratic V/F, Open Loop PM Motor Control
  • Pump/Fan: Built-in PID, Sleep/Wake, Lead-Auxiliary Pump Selection, Booster Staging
  • Communication: Built-in Modbus RTU via RJ45 (RS485); optional Profibus DP
  • Frequency range: 0.5 – 500 Hz
  • Frame: S1, 145×297×203 mm, 3.135 kg
  • Standards: CE, RoHS, IEC 61800-3/-5-1
SKU: XD2000-07P2-4B1121

XD2000-07P2-4B1121 — 2.2kW/3kW Three-Phase Variable Frequency Drive (415V)

The Lauritz Knudsen xD2000 XD2000-07P2-4B1121 is a 2.2kW/3kW 415V VFD. It is built for fan, pump, compressor, and other non-regenerative process applications. Because it runs on a 380–460VAC (-15/+10%), 3-phase, 50/60Hz supply, it fits standard industrial power without extra conditioning.

The drive combines a compact Frame 1 footprint with an inbuilt EMC filter and galvanic isolation. In addition, drives from 4kW ND onward add a built-in DC reactor, which reduces harmonics and supports longer motor cable runs. Explore the complete range in our Lauritz Knudsen variable frequency drives collection.

XD2000-07P2-4B1121 2.2kW/3kW 415V VFD — front view

2.2kW/3kW 415V VFD – Control & Motor Compatibility

The xD2000 supports V/F control (5-point), Slip Compensation, and quadratic V/F energy-saving. It also provides Open Loop control of Permanent Magnet synchronous motors, so one drive platform covers both induction and PM motor types.

Overload capacity reaches 150% of rated current for Heavy Duty use and 110% for Normal Duty use. The output frequency range spans 0.5–500Hz as well. As a result, this 2.2kW/3kW 415V VFD is a strong fit for fans, pumps, compressors, and general utility process applications. These applications typically do not require regenerative braking.

XD2000-07P2-4B1121 2.2kW/3kW 415V VFD — side view

2.2kW/3kW 415V VFD – Pump & Fan-Specific Features

Built-in PID control (AHU, fan, pump, compressor) supports 4 preset PID references. It also includes PID wake-up/sleep with Sleep Boost, plus predictive speed (pre-PID frequency), so the 2.2kW/3kW 415V VFD can hold pressure or flow targets without an external controller.

Pump and compressor specific logic adds lead (master) and auxiliary pump selection with fixed and variable speed. It also supports FIFO/FILO staging and booster-pump control with staging and destaging. Stall prevention (deceleration ramp adaptation and current limiting), skip frequency, catch-on-the-fly (flying start), and DC braking during stopping round out the application toolkit.

2.2kW/3kW 415V VFD – Built-in Modbus & Optional Profibus DP

A front-face RJ45 port gives native 2-wire RS485 Modbus RTU connectivity (4800–38400 bps). As a result, the XD2000-07P2-4B1121 links directly to a PLC, HMI, or SCADA system without extra hardware, which makes this 2.2kW/3kW 415V VFD easy to fold into an existing automation network.

An optional Profibus DP card (9-pin Sub-D, 9.6–12000 kbps with automatic baud-rate detection) adds native drive profile support (CiA®402) and PROFIdrive. It also allows quick setup from the drive side and supports two masters (MS0/MS1). Detachable, IP21-rated basic LCD keypads (4-line, white backlight, 6 languages, store/download configurations) are standard; an advanced graphical LCD keypad is available as an option.

XD2000-07P2-4B1121 2.2kW/3kW 415V VFD — top view

2.2kW/3kW 415V VFD – Applications

This 2.2kW/3kW 415V VFD is widely used for HVAC fans and AHUs, water and booster pumps, and compressors. It also suits other non-regenerative utility and process applications across buildings, water treatment, and light industry.

Its enclosure is IP20 (IP4X on top with the vent cover). The inbuilt EMC filter complies with IEC/EN 61800-3 Category C3 in Environment 1 or 2 for CE marking, and the maximum shielded cable length is 50m. Therefore, installers get CE-ready EMC performance without adding an external filter.

Technical Specifications

ModelXD2000-07P2-4B1121
Output Power2.2 kW (Heavy Duty) / 3 kW (Normal Duty)
Output Current5.6 A (HD) / 7.2 A (ND)
Supply Voltage380–460VAC (-15/+10%), 3-phase, 50/60Hz
Frame SizeFrame 1 (S1)
Dimensions (W×H×D)145 × 297 × 203 mm
Weight3.135 kg
EnclosureIP20 (IP4X on top with vent cover)
Output Frequency0.5 – 500 Hz
Control ModesV/F, V/F 5-point, Slip Compensation, V/F Energy Saving & Quadratic V/F, Open Loop Synchronous (PM) Motor Control
Overload Capacity150% (Heavy Duty) / 110% (Normal Duty) of rated current for 1 min
Efficiency at Full Load96.6 – 98.3%
CommunicationBuilt-in Modbus RTU via RJ45 (2-wire RS485); optional Profibus DP
Operating Temperature-15 to +45°C (without derating), up to +60°C with derating
DC Reactor2.076 mH – 15A (not built-in)
Recommended MPCBMOG-H1M 16A
Recommended MCCBDZ1-160N 16A
Recommended Main ContactorMO 25 / MNX 25 (25A)
Cable Sizing (Supply & Output)1.5 (16) mm² (AWG)
StandardsCE, RoHS, IEC 61800-3, IEC 61800-5-1, IEC 60721-3

Why source it from Konica Automation?

Konica Automation is an authorised distributor for Lauritz Knudsen Electrical & Automation and supplies genuine drives with manufacturer specifications. Our engineers help you select and size the right drive, and support you through commissioning, spares and after-sales service across India. Browse the full Lauritz Knudsen range or contact us with your application details.

XD2000-07P2-4B1121 2.2kW/3kW 415V VFD — bottom view

Frequently Asked Questions

Does the XD2000-07P2-4B1121 need braking capability? No — the xD2000 series is designed for non-regenerative fan, pump, and compressor applications that do not require dynamic braking.

Can it control Permanent Magnet (PM) motors? Yes, the xD2000 supports Open Loop control of Permanent Magnet synchronous motors in addition to standard induction motors.

Does it come with a DC reactor? Yes, a DC reactor is built in from 4kW(ND) ratings onward, reducing harmonics by roughly 40% at rated load.